| DC to DC Converters |
Convert any instrumentation DC Voltage or Current
signal to an any isolated DC Voltage or Current signal |
SC |
( ) 4000 ( ) |
| AC to DC Converters |
Convert any instrumentation AC Voltage or
Current signal to an any isolated DC Voltage or Current signal |
SC |
( ) 4001 ( ) |
| Thermocouple to DC Converters |
Convert any instrumentation Thermocouple signal to
an any isolated DC Voltage or Current signal |
SC |
( ) 4002 ( ) |
| RTD or Potentiometer to DC Converters |
Convert any instrumentation RTD or
Potentiometer signal to an any isolated DC Voltage or Current signal |
SC |
( ) 4003 ( ) |
| Adder / Subtractors |
Add and subtract up to 4 DC Voltage or Current
signals to create a single DC Voltage or Current signal or add up to 3
totalizer pulses |
SC |
( ) 4005 ( ) |
| Linearizers |
Convert and linearize any instrumentation DC
Voltage or DC Current signal to any DC Voltage or DC Current signal (
linearization can be exponential, log, anti-log or empirical) |
SC |
( ) 4006 ( ) |
| Analog Multipliers / Dividers |
Multiply or divide any two instrumentation DC
Voltage or DC Current signals with the resultant being any DC Voltage or
DC Current signal |
SC |
( ) 4008 ( ) |
| Integrators (Totalizers) |
Convert any instrumentation DC Voltage or DC
Current signal to a proportional pulse rate |
SC |
( ) 4011 ( ) |
| Pulse to Pulse Scalers |
Divides or multiplies any instrumentation pulse
signal rate to resulting a scaled pulse rate |
SC |
( ) 4017 ( ) |
| Strain Gage to DC Converters |
Convert any instrumentation Strain Gage signal to
any DC Voltage or DC Current signal |
SC |
( ) 4018 ( ) |
| Sample or Track or Peak and Hold |
Convert any instrumentation DC Voltage or DC
Current signal to any DC Voltage or DC Current signal and either sample,
hold or select the peak of the signal |
SC |
( ) 4020 ( ) |
| Ratio and Bias Converters |
Convert and scale any instrumentation DC Voltage
or DC Current signals to any DC Voltage or DC Current signal with ratio
and bias adjustments |
SC |
( ) 4028 ( ) |
| Signal Rate of Change Limiters |
Convert any instrumentation DC Voltage or DC
Current signal to any DC Voltage or DC Current signal and limit its rate
of change |
SC |
( ) 4029 ( ) |
| DC Input Alarms / Controllers |
Accepts any instrumentation DC Voltage or DC
Current signal and operates a relay based on setpoints, deadband and
time delay adjustments |
SC |
( ) 4034 ( ) |
| Thermocouple Alarms / Controllers |
Accepts any instrumentation Thermocouple signal
and operates a relay based on setpoints, deadband and time delay
adjustments |
SC |
( ) 4039 ( ) |
| RTD/Potentiometer Alarms / Controllers |
Accepts any instrumentation Resistance signal and
operates a relay based on setpoints, deadband and time delay
adjustments |
SC |
( ) 4041 ( ) |
| Positioners / Controllers |
Accepts any instrumentation DC Voltage, DC
Current signal or resistance and operates two relays or varies a DC
Voltage or DC Current based on the difference between a setpoint and a
variable |
SC |
( ) 4045 ( ) |
| AC Input Alarms / Controllers |
Accepts any instrumentation AC Voltage or AC
Current signal and operates a relay based on setpoints, deadband and
time delay adjustments |
SC |
( ) 4047 ( ) |
| Analog to Pulse Duration Converters |
Convert any instrumentation DC Voltage, DC
Current, Potentiometer, RTD, Frequency or Strain Gage signal to any
instrumentation pulse duration signal |
SC |
( ) 5000 ( ) |
| Pulse Duration Analog Converters |
Convert any instrumentation Pulse Duration
signal to any proportional DC Voltage or DC Current |
SC |
( ) 5100 ( ) |
| High, Low or Median Selectors |
Select the highest, median, or lowest of any four
instrumentation DC Voltage or DC Current signals and convert it to any
DC Voltage or DC Current signal |
SC |
( ) 4010 ( ) |
| Pulse Count to Analog Converters |
Convert an accumulation of pulses to a
proportional DC Voltage or DC Current |
SC |
( ) 4050 ( ) |
| Data Handler |
Single point, multi-site, universal,
microcontroller based RTU |
DH |
( ) 9000 ( ) |
| Integrated Control Station |
Integrated Control Station |
ICS |
( ) 5300 ( ) |
| General Purpose Modem |
Comm Manager |
GPM |
( ) 5315 ( ) |
| Universal WEB Station |
Connect AGM and other approved manufacturers
products to the WEB for data access through local and wide area
networks |
UWS |
( ) 7000 ( ) |
| AC to DC Power Supplies |
Converts AC line voltage to a regulated DC
voltage |
SC |
( ) 4552 ( ) |
| AC to DC Power Supplies w/Clock |
Converts AC line voltage to a regulated DC voltage
and PDC |
SC |
( ) 4562 ( ) |
| Signal Amplitude Limiters |
Convert any instrumentation DC Voltage or
Current signal to an any isolated/Non-Isolated DC Voltage or Current
signal, Hi/Lo Limits 100% Adjustable |
SC |
( ) 4027 ( ) |
| Compond Flow Signal Selectors |
Accepts a low and high flow signal input and
provides a composite flow signal output |
SC |
( ) 4014 ( ) |
| Accessories |
Accessories |
SC |
( )
8000 ( ) |
| Accessory |
Various Accessory Options |
ACC |
( ) 5500 ( ) |
| Spread Spectrum Radio |
Spread Spectrum Radio |
SSR |
( ) 5017 ( ) |
| DC Input Alarms / Controllers |
Accepts any instrumentation DC Voltage or DC
Current signal and operates a relay based on setpoints, deadband and
time delay adjustments |
SC |
( ) 4035 ( ) |
| Thermocouple Alarms / Controllers |
Accepts any instrumentation Thermocouple signal
and operates a relay based on setpoints, deadband and time delay
adjustments |
SC |
( ) 4040 ( ) |
| RTD/Potentiometer Alarms / Controllers |
Accepts any instrumentation Resistance signal
and operates a relay based on setpoints, deadband and time delay
adjustments |
SC |
( ) 4042 ( ) |
| AC Input Alarms / Controllers |
Accepts any instrumentation AC Voltage or AC
Current signal and operates a relay based on setpoints, deadband and
time delay adjustments |
SC |
( ) 4048 ( ) |
| Pulse Frequency to Analog Converters |
Convert any instrumentation low rate Pulse
Frequency signal to any proportional DC Voltage or DC Current |
SC |
( ) 5107 ( ) |