4230 Flow Meter
Bubbler level
sensing provides the most accurate measurement.
Click Here if you
would like to purchase an ISCO 4230 Flow Meter Online
Isco
4230 Bubbler Flow Meters use an internal air compressor to force a metered
amount of air through a bubble line submerged in the flow channel. By measuring
the pressure needed to force air bubbles out of the line, the flow level is
accurately determined.
Measurement accuracy of the 4230 is not affected by wind, steam, foam or
turbulence, nor by suspended solids and rapidly changing head heights that can
cause problems for some bubbler flow meters. Because only the bubble tube
contacts the flow, corrosive chemicals are not a problem. The 4230 also resists
damage by lightning and debris, making it ideal for stormwater applications.
Automatic Drift Compensation makes Isco bubbler flow meters the most accurate
level measurement technology. In standby applications such as stormwater runoff
monitoring, Automatic Drift Compensation also allows the 4230 to maintain
calibration indefinitely. Automatic bubble line purging prevents clogging, and
the meter's internal software senses rapidly rising heads and increases the
bubble rate to maintain maximum accuracy.
Standard Features
- Built-in flow conversions for most applications, including Manning
formula, data points, or equation for special situations.
- Two-line x 80-character backlit LCD.
- Choice of standard (10 ft) and extended (30 ft) level measurement range.
- Built-in dot matrix printer gives you an accurate, on-site printout
- Internal memory stores over 2 months of flow, rainfall, parameter, and
sample data at 15 minute intervals.
- Automatic Drift Compensation eliminates effects of transducer drift and
allows the 4230 to maintain level calibration indefinitely
- Interfacing for Sampler activation, connection to multiparameter water
quality sonde, alarm outputs
Applications
- Portable and fixed-site flow measurement with weirs and flumes
- Pretreatment Compliance
- Stormwater Runoff Monitoring
- Permit Enforcement
- Sewer Flow Monitoring
- Combined Sewer Overflow Studies
- Wastewater Treatment Plant Operations
- Inflow and Infiltration Studies
- River and Stream Gauging
Options and Accessories
- Optional telephone modem - provides remote data retrieval, voice
messaging, and dial-out alarm conditions
- Analog Outputs - up to 3 isolated internal 4-20 mA outputs
- Metering inserts for street level installation of bubble line in round
pipes from 6 to 12 inches in diameter
- Non-resettable totalizer
- 674 Rain Gauge
- 581 RTD data retrieval device downloads up to 20 meters
- 270 DO module adds dissolved oxygen measurement/logging
- 201 pH module adds pH and temperature measurement/logging
- YSI 600 Multi-Parameter Water Quality Monitor
- Suspension equipment (to hang flowmeter in manhole)
Specifications
| Size (H x W x
D): |
17.0 x 11.5 x
10.5 in. (43 x 29 x 26.7 cm) (without power source) |
| Weight: |
17.3 lbs (7.8
kg) (without power source) |
| Material: |
High-impact
molded polystyrene structural foam |
| Enclosure: |
NEMA 4X (iP65) |
| Power: |
12 to 14V DC, 16
mA average at 12.5V DC |
| Typical
Battery Life (printer set at 1 in./hr (2.5 cm/hr), 1 bubble per second,
15 minute purge, and continuous level reading interval) |
| 934
Nickel-Cadmium Battery: |
7 to 10 days |
| 946 Lead-Acid
Battery: |
10 to 15 days |
| 948 Lead-Acid
Battery: |
2 to 3 months |
| Program Memory: |
Non-volatile,
programmable flash. Updateable without opening enclosure. |
| Display: |
Backlit LCD,
2-line, 80-character (5.5 mm high x 3.2 mm wide) |
| Level-to-Flow
Rate Conversions |
| Weirs: |
V-notch,
rectangular with and without end contractions, Cipolletti |
| Flumes: |
Parshall,
Palmer-Bowlus, Leopold-Lagco,Trapezoidal, H, HS, HL |
| Manning Formula: |
Round,
U-channel, rectangular, trapezoidal Data Points Four sets of 50
level-flow rate points Equation Two-term polynomial |
| Totalizers |
| LCD: |
9-digit,
floating decimal point, resettable |
| Mechanical
(optional): |
7-digit, non-resettable |
| Inputs
and outputs |
| Rain Gauge
Input: |
Contact closure,
normally open. Resolution 0.01 or 0.004 in ( 0.25 or 0.1 mm) |
| Parameter
Inputs: |
pH, dissolved
oxygen, conductivity, and temperature (with optional YSI 600 sonde); pH
and temperature (with optional Isco 201 Parameter Module); or dissolved
oxygen and temperature (with optional Isco 270 Parameter Module) |
| Sampler
Activation Conditions: |
Enabled,
disabled, AND and OR combinations of any two of level, flow rate,
rainfall, pH, DO, conductivity, and temperature |
| Sampler Pacing
Output: |
12V pulse |
| Sampler Input: |
Event mark,
bottle number |
| Printer |
| Recording Modes: |
Up to 3 graphs
of level, flow rate, pH, DO, conductivity, and temperature vs time;
includes totalized flow. Rainfall and sampler events (time and bottle
number) are also recorded |
| Speed: |
Off, 0.5, 1, 2,
4 in/hr (1.25, 2.5, 5, 10 cm/hr) |
| Recording Span: |
User selectable
with multiple over-ranges |
| Resolution: |
1/240 of
recording span |
| Reports Printed: |
Flow meter
program, 2 independent time interval reports, flow meter history,
sampler history |
| Interval Report
Contents: |
Site number;
time interval; total flow; minimum, maximum, and average flow rate,
level, pH, DO, conductivity, and temperature, and time of occurrence;
interval flow; total rainfall; number of samples, flow meter history and
sampler history |
| Character Size (HxW): |
0.09 x 0.07 in
(2.4 x 1.7 mm) |
| Paper: |
4.5 in. wide x
65 ft. (11.4 cm x 19.8 m), plain white paper, replaceable roll |
| Ribbon: |
19.7 ft. (6.0 m)
black nylon, replaceable |
| Data
Storage Memory |
| Capacity: |
80,000 bytes
(approx. 40,000 readings) divided into a maximum of 12 memory
partitions. Equal to 100 days of level, rainfall, pH, DO, conductivity,
and temperature readings at 15 minute intervals, plus 3,000 sample
events. Optional expansion to 473,000 bytes (approx 236,500 readings) |
| Setup and Data
Retrieval: |
IBM PC or
compatible computer with Isco Flowlink 4 for Windows |
| Communication: |
Direct
connection, optional internal 2400 baud telephone modem with voice
messaging |
| Data Retrieval
(optional): |
Isco 581 Rapid
Transfer Device (RTD) |
| Voice Messaging
(with optional internal modem): |
Calls up to 5
telephone numbers with programmable delay between calls, activated based
on AND and OR combinations telephone of any two of level, flow rate,
rainfall, pH, DO, conductivity, and temperature |
| Analog Outputs: |
(optional) Up to
3 isolated internal outputs, 0 to 20 mA or 4 to 20 mA, scaleable based
on level, flow rate, pH, DO, conductivity, or temperature, into a
maximum of 750 ohms each |
| Relay Outputs: |
2 form C relays
with field selectable trip points based on flow rate (with optional
High/Low Alarm Relays) |
| Serial Output: |
Current status
and readings, in response to command or automatically at selectable time
intervals, ASCII comma separated values at 1200, 2400, 4800, or 9600
baud |
| Storage
Temperature: |
-40° to 140°F
(-40° to 60°C) |
| Operating
Temperature: |
0° to 140°F
(-18° to 60°C) |
| Bubbler |
| Range: |
0.1 to 10 ft
(0.03 to 3.05 m) |
| Level
Measurement Accuracy (Non-linearity, repeatability, and hysteresis at 25°C
(77°F). Max error (±) for indicated level range. |
| 0.1 to 5.0 ft
(0.03 to 1.52 m): |
±0.005 ft (±0.002
m) |
| 0.1 to 7.0 ft
(0.03 to 2.13 m): |
±0.01 ft (±0.003
m) |
| 0.1 to 10 ft
(0.03 to 3.05 m): |
±0.035 ft (±0.011
m) |
| Temperature
Coefficient (Maximum error (±) per degree change over compensated
range) |
| For level in
feet: |
±0.0003 x level
x temperature change from 72°F |
| For level in
meters: |
±0.0009 x level
x temperature change from 22°C |
| Automatic Drift
Correction: |
After a 5 minute
warm-up period, zero level is corrected to ±0.002 ft. (±0.0006 m) at
intervals between 2 and 15 minutes |
| Long-Term Level
Calibration Change: |
Typically 0.5%
of reading per year |
| Ambient Range: |
0° to 140°F
(-18° to 60°C) |
| Compensated
Range: |
32° to 140°F
(0° to 60°C) |
|