Products
Services
Customer Support
Events
News

Employment
Opportunities
Contact Us
Links

Company

SCADA Systems, RTUs, PLCs


Buy Products Online

Customer Service
(800) 649-4287

Terms and Conditions of Sale

Privacy Statement

 

4220 Flow Meter
Submerged probe accuracy unaffected by wind, steam, foam, turbulence or air temperature change.

The probe on the Isco 4220 uses a differential pressure transducer to measure the depth of the liquid. The probe accurately senses pressure even when covered with silt and sand, and the venting system automatically compensates for changes in atmospheric pressure. This technology provides accurate measurement at sites where wind, steam, foam, turbulence, or air temperature fluctuations exist.

Isco Submerged Probes are UL Classified for Class I, Division 1, Groups A, B, C & D hazardous locations when installed using the Intrinsically Safe Barrier and Quick Disconnect Box. This makes the submerged probe safe to use in locations where flammable gases may be present.

Isco mounting rings make it easy to install the probe in round pipes and manhole inverts. With the Isco Street Level Installation Tool, you can install your monitoring system from ground level, eliminating the costs and hazards of entering manholes. Most flumes are available with an integral recess for mounting an Isco Submerged Probe.

Standard Features

  • Built-in level-to-flow conversions for most applications.
  • Choice of standard (10 ft) and extended (30 ft) level measurement range.
  • Venting system automatically compensates for atmospheric pressure changes
  • Two-line x 80-character backlit LCD.
  • Built-in dot matrix printer gives you an accurate, on-site printout
  • Internal memory stores over 2 months of data.
  • Easy interfacing for Sampler, water quality sonde, alarm outputs

Applications

  • Flow measurement in Class 1 Div 1 locations (Flowmeter in safe area)
  • Pretreatment Compliance
  • Stormwater Runoff Monitoring
  • Permit Enforcement
  • Sewer Flow Monitoring
  • Combined Sewer Overflow Studies
  • Wastewater Treatment Plant Operations
  • Inflow and Infiltration Studies
  • River and Stream Gauging

Options and Accessories

  • Internal telephone modem
  • Analog Outputs (up to 3)
  • Intrinsically Safe Barrier (for installing probe in Class 1 Div 1 location)
  • Mounting rings and sensor carrier (for installing probe in round pipes from 6 to 15 inches)
  • Non-resettable totalizer
  • 674 Rain Gauge
  • 581 RTD data retrieval device
  • 270 DO module adds dissolved oxygen measurement/logging
  • 201 pH module adds pH and temperature measurement/logging
  • YSI 600 Multi-Parameter Water Quality Monitor
  • Suspension equipment (to hang flowmeter in manhole)

Specifications
Size (H x W x D): 17.0 x 11.5 x 10.5 in. (43 x 29 x 26.7 cm) (without power source)
Weight: 17.3 lbs (7.8 kg) (without power source)
Material: High-impact molded polystyrene structural foam
Enclosure: NEMA 4X (iP65)
Program Memory: Non-volatile, programmable flash. Updateable without opening enclosure.
Display: Backlit LCD, 2-line, 80-character (5.5 mm high x 3.2 mm wide)
Storage Temperature: -40° to 140°F (-40° to 60°C)
Operating Temperature: 0° to 140°F (-18° to 60°C)
Power: 12 to 14V DC, 24 mA average at 12.5V DC
Typical battery life (printer set at 1 in/hr, 1 minute level reading interval)
934 NiCad Battery: 8 to 11 days
946 Lead-Acid Battery: 12 to 16 days
948 Lead-Acid Battery: 21/2 to 3 months
Submerged probe
Dimensions: 9.5 x 0.875 in (24.1 x 2.2 cm)
Cable: Standard range probe - 25 ft x 0.3 in (7.6 m x 0.8 cm); Extended range probe - 50 ft x 0.3 in (15.2 m x 0.8 cm)
Level Measurement Method: Submerged pressure transducer mounted in the flow stream
Transducer Type: Differential linear integrated circuit pressure transducer
Hazardous Location Rating: UL Classified for Class I, Division 1, Groups A, B, C, & D locations, when installed with Isco Intrinsically Safe Barrier and Quick Disconnect Box per control drawing 60-3403-131
Operating Temperature: 32° to 160°F (0° to 71°C)
Compensated Temperature: 32° to 100°F (0° to 38°C)
Level Measurement Range
Standard rangep probe: 0.1 to 10 ft (0.03 to 3.05 m)
Extended range probe: 0.1 to 30 ft (0.03 to 9.14 m)
Maximum Allowable Level: Standard range probe - 20 ft (6.1 m); Extended range probe - 40 ft (12.2 m)
Level Measurement Accuracy (at 25°C (77°F) - Max error (±) for indicated level range)
Standard range probe
0.1 to 5.0 ft (0.03 to 1.52 m): ±0.01 ft (±0.003 m)
0.1 to 7.0 ft (0.03 to 2.13 m): ±0.03 ft (±0.009 m)
0.1 to 10 ft (0.03 to 3.05 m): ±0.10 ft (±0.03 m)
Extended range probe
0.1 to 15 ft (0.03 to 4.57 m): ±0.03 ft (±0.009 m)
0.1 to 21 ft (0.03 to 6.40 m): ±0.09 ft (±0.027 m)
0.1 to 30 ft (0.03 to 9.14 m): ±0.30 ft (±0.09 m)
Temperature Coefficient (Maximum error per degree of temperature change over compensated range)
Standard range probe
0.1 to 4.0 ft (0.03 to1.22m): ±0.005ft/°F (±0.0027m/°C)
4.0 to 10 ft (1.22 to 3.05m): ±0.007ft/°F (±0.0038m/°C)
Extended range probe
0.1 to 30 ft (0.03 to 9.14 m): ±0.008ft/°F (±0.0044 m/°C)
Materials
Submerged probe: Type 316 stainless steel, chlorinated polyvinyl chloride (CPVC)
Cable: Polyvinyl chloride (PVC)